PRODUCTS
- 1-Anaesthesia Products
- 2-Dental Products
- 3-Diagnostics Products
- 4-Emergency & First Aid
- 5-Hospital Furniture
- 6-Laboratory Products
- 7-Dressing&Wound Care
- 8-Medical Disposable
- 9-Non Woven Products
- 10-Orthopaedic
- 11-Rehabilitation & Aid
- 12-Sterilization
- 13-Interventional
- 14-Others
NEWS
- 2024-07-05meeting Luckmed's business agen
- 2017-08-01Medic & Medlab East Africa
CONTACT US
- Add: 5th Floor,Wanke Center,No.2,Heilongjiangnan Road,Qingdao,China
- Tel: +86 18605320580
- Fax: 0532-87620082
- Email: info@luckmed.com
Your position: Home > Products > 4-Emergency & First Aid > 4-8 Defibrillator Monitor >
Defibrillator Monitor
- TEL:+86 18605320580
- EMAIL:info@luckmed.com
- Product description: DEFIBRILLATOR MONITOR MONOPHASIC Features Monophaisc Technical specifications DEFIBRILLATOR. (1) Defibrillator type Manual,synchronized,asynchronized (2) Energy accuracy +1% (3) Energy selection 0, 20, 50, 100, 160, 250, 300, 360 joules (no
Product introduction
DEFIBRILLATOR MONITOR
Technical specifications
(1) Defibrillator type Manual,synchronized,asynchronized
(2) Energy accuracy ∠+1%
(3) Energy selection 0, 20, 50, 100, 160, 250, 300, 360 joules (nominal at a resistance of 50)
(4) Charging time Maximum 10 seconds to 360 Joules
(5) Standard Adult/Pediatric Paddles Reusable external adult paddles(pediatric paddles integrated)
Power requirements
(a) AC Power supply 100V~240V,50Hz/60 Hz
(b) Vehicle Voltage(Option) DC 12V
Internal Battery Backup
(1)Battery type Rechargeable lead-acid battery (12V 2.0Ah X2)
(2)Charging time Time-Minimum of 4 hours for full charging
(3)Battery charging During AC Power Supply operation of the device.
(4)Charging /Low Battery Indication Red LED
(5)Battery Capacity 100% of the battery will provide 120-min of monitoring; and 35 discharges at 360 joules.
Display
-LCD Dimensions 10.4 inch
-Type High resolution true-color graphic LCD
ECG
ECG lead: Ⅰ, Ⅱ, Ⅲ, AVR, AVL, AVF, V1~V6
S-T segment analysis: -2.0~2.0mv
Arrhythmia analysis: yes
Protection: With stand 4000vAc/50Hz voltage in isolation and work against electrosurgical knife and defibrillation
Respiration
Measurement method: Thoracic impedance
NIBP
Working mode: Manual/Automatic/stat
Method: Automatic oscillation
Cuff type: standard Adult; optional Pediatric/Neonatal
Temperature
Measurement range 20~45℃
Resolution 0.1℃
Pulse Oximetry(spO2)
Display :spo2 value, pulse histogram, waveform, Pulse
Range: 0~99%for adult, pediatric and neonatal patients
Probe :standard adult finger clip
optional pediatric Y-type clip and neonatal wrap
Pulse range
Pulse range: 0-255bpm
Standard parameter & configuration
ECG/ RESP/SPO2/TEMP/PR/NIBP/DEFIBRILLATOR
Optional parameter
Recorder, Li-ion battery (11.1V 4Ah X2)
(1) Defibrillator type Manual,synchronized,asynchronized
(2) Energy accuracy ∠+1%
(3) Energy selection 0, 20, 50, 100, 160, 250, 300, 360 joules (nominal at a resistance of 50)
(4) Charging time Maximum 10 seconds to 360 Joules
(5) Standard Adult/Pediatric Paddles Reusable external adult paddles(pediatric paddles integrated)
Power requirements
(a) AC Power supply 100V~240V,50Hz/60 Hz
(b) Vehicle Voltage(Option) DC 12V
Internal Battery Backup
(1)Battery type Rechargeable lead-acid battery (12V 2.0Ah X2)
(2)Charging time Time-Minimum of 4 hours for full charging
(3)Battery charging During AC Power Supply operation of the device.
(4)Charging /Low Battery Indication Red LED
(5)Battery Capacity 100% of the battery will provide 120-min of monitoring; and 35 discharges at 360 joules.
Display
-LCD Dimensions 10.4 inch
-Type High resolution true-color graphic LCD
ECG
ECG lead: Ⅰ, Ⅱ, Ⅲ, AVR, AVL, AVF, V1~V6
S-T segment analysis: -2.0~2.0mv
Arrhythmia analysis: yes
Protection: With stand 4000vAc/50Hz voltage in isolation and work against electrosurgical knife and defibrillation
Respiration
Measurement method: Thoracic impedance
NIBP
Working mode: Manual/Automatic/stat
Method: Automatic oscillation
Cuff type: standard Adult; optional Pediatric/Neonatal
Temperature
Measurement range 20~45℃
Resolution 0.1℃
Pulse Oximetry(spO2)
Display :spo2 value, pulse histogram, waveform, Pulse
Range: 0~99%for adult, pediatric and neonatal patients
Probe :standard adult finger clip
optional pediatric Y-type clip and neonatal wrap
Pulse range
Pulse range: 0-255bpm
Standard parameter & configuration
ECG/ RESP/SPO2/TEMP/PR/NIBP/DEFIBRILLATOR
Optional parameter
Recorder, Li-ion battery (11.1V 4Ah X2)
PREVIOUS:没有了
NEXT:Portable AED Automated External Defibrillator Monitor with E